Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
Mais filtros










Base de dados
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-38082891

RESUMO

In the Neonatal Intensive Care Unit (NICU), infants' vital signs are monitored on a continuous basis via wired devices. These often interfere with patient care and pose increased risks of skin damage, infection, and tangling around the body. Recently, a wireless system for neonatal monitoring called ANNEⓇ One (Sibel Health, Chicago, USA) was developed. We designed an ongoing study to evaluate the feasibility, reliability and accuracy, of using this system in the NICU. Vital signals were simultaneously acquired by using the standard, wired clinical monitor and the ANNEⓇ device. Data from 10 NICU infants were recorded for 8 hours per day during 4 consecutive days. Initial analysis of the heart rate (HR) data revealed four problems in comparing the signals: 1) gaps in the signals - periods of time for which data were unavailable, 2) wired and wireless signals were sampled at different rates, 3) a delay between the sampled values of wired and wireless signals, and 4) this delay increased with time. To address these problems, we developed a pre-processing algorithm that interpolated samples in short gaps, resampled the signals to an equal rate, estimated the delay and drift rate between corresponding signals, and aligned the signals. Applications of the pre-processing algorithm to 40 recordings demonstrated that it was very effective. A strong agreement between wireless and wired HR signals was seen, with an average correlation of 0.95±0.04, a slope of 1.00, and a variance accounted for 89.56±7.62%. Bland-Altman analysis showed a low bias across the ensemble, with an average difference of 0.11 (95% confidence interval of -0.02 to 0.24) bpm.Clinical relevance- This algorithm provides the means for a detailed comparison of wired and wireless monitors in the NICU.


Assuntos
Determinação da Frequência Cardíaca , Unidades de Terapia Intensiva Neonatal , Recém-Nascido , Humanos , Reprodutibilidade dos Testes , Tecnologia sem Fio , Monitorização Fisiológica
2.
PeerJ ; 11: e15578, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-37397010

RESUMO

Background: Continuous monitoring of vital signs and other biological signals in the Neonatal Intensive Care Unit (NICU) requires sensors connected to the bedside monitors by wires and cables. This monitoring system presents challenges such as risks for skin damage or infection, possibility of tangling around the patient body, or damage of the wires, which may complicate routine care. Furthermore, the presence of cables and wires can act as a barrier for parent-infant interactions and skin to skin contact. This study will investigate the use of a new wireless sensor for routine vital monitoring in the NICU. Methods: Forty-eight neonates will be recruited from the Montreal Children's Hospital NICU. The primary outcome is to evaluate the feasibility, safety, and accuracy of a wireless monitoring technology called ANNE® One (Sibel Health, Niles, MI, USA). The study will be conducted in 2 phases where physiological signals will be acquired from the standard monitoring system and the new wireless monitoring system simultaneously. In phase 1, participants will be monitored for 8 h, on four consecutive days, and the following signals will be obtained: heart rate, respiratory rate, oxygen saturation and skin temperature. In phase 2, the same signals will be recorded, but for a period of 96 consecutive hours. Safety and feasibility of the wireless devices will be assessed. Analyses of device accuracy and performance will be accomplished offline by the biomedical engineering team. Conclusion: This study will evaluate feasibility, safety, and accuracy of a new wireless monitoring technology in neonates treated in the NICU.


Assuntos
Unidades de Terapia Intensiva Neonatal , Sinais Vitais , Recém-Nascido , Criança , Humanos , Monitorização Fisiológica , Taxa Respiratória , Frequência Cardíaca
3.
Eur J Pediatr ; 182(5): 1991-2003, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-36859727

RESUMO

The purpose of this study is to provide a structured overview of existing wireless monitoring technologies for hospitalized children. A systematic search of the literature published after 2010 was conducted in Medline, Embase, Scielo, Cochrane, and Web of Science. Two investigators independently reviewed articles to determine eligibility for inclusion. Information on study type, hospital setting, number of participants, use of a reference sensor, type and number of vital signs monitored, duration of monitoring, type of wireless information transfer, and outcomes of the wireless devices was extracted. A descriptive analysis was applied. Of the 1130 studies identified from our search, 42 met eligibility for subsequent analysis. Most included studies were observational studies with sample sizes of 50 or less published between 2019 and 2022. Common problems pertaining to study methodology and outcomes observed were short duration of monitoring, single focus on validity, and lack information on wireless transfer and data management.  Conclusion: Research on the use of wireless monitoring for children in hospitals has been increasing in recent years but often limited by methodological problems. More rigorous studies are necessary to establish the safety and accuracy of novel wireless monitoring devices in hospitalized children. What is Known: • Continuous monitoring of vital signs using wired sensors is the standard of care for hospitalized pediatric patients. However, the use of wires may pose significant challenges to optimal care. What is New: • Interest in wireless monitoring for hospitalized pediatric patients has been rapidly growing in recent years. • However, most devices are in early stages of clinical testing and are limited by inconsistent clinical and technological reporting.


Assuntos
Criança Hospitalizada , Sinais Vitais , Humanos , Criança , Hospitais , Tecnologia sem Fio
4.
OTO Open ; 7(1): e230, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36998570

RESUMO

Sub-Saharan Africa has a high otolaryngologic disease burden exacerbated by an inadequate number of otolaryngologists. The Otolaryngology department at Mbarara University of Science & Technology in Uganda is addressing this problem by having created Uganda's second national residency training program in 2010. We chronicled an early period in the program's development by reporting surgical case quantity and complexity, as defined by "key indicator procedure" classification per the United States Accreditation Council for Graduate Medical Education, and interpreting it with respect to a timeline of significant events. Procedure complexity, but not total number per year, increased over the study period-KIPs increased from 3% in 2012 (6 of 175 total procedures) to 29% in 2016 (35 of 135 total procedures). During this period of complexity increase, operating room capacity expanded, faculty received advanced training and increased in number, and operative equipment improved.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA
...